Task 3670886

Name virtualbox_28_35599_1685430002.4843874_0
Workunit 1953908
Created 30 May 2023, 7:00:05 UTC
Sent 30 May 2023, 7:21:14 UTC
Report deadline 6 Jun 2023, 7:21:14 UTC
Received 30 May 2023, 7:22:24 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 1 (0x00000001) Unknown error code
Computer ID 563
Run time 11 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 21.41 GFLOPS
Application version virtualbox v1.00 (vbox64_mt)
windows_x86_64
Peak working set size 6.88 MB
Peak swap size 1.98 MB
Peak disk usage 2.08 MB

Stderr output

<core_client_version>7.22.0</core_client_version>
<![CDATA[
<message>
Incorrect function.
 (0x1) - exit code 1 (0x1)</message>
<stderr_txt>
2023-05-30 09:21:20 (8268): Detected: vboxwrapper 26206
2023-05-30 09:21:20 (8268): Detected: BOINC client v7.22.0
2023-05-30 09:21:21 (8268): Detected: VirtualBox VboxManage Interface (Version: 7.0.8)
2023-05-30 09:21:22 (8268): Feature: Checkpoint interval offset (495 seconds)
2023-05-30 09:21:22 (8268): Detected: Minimum checkpoint interval (600.000000 seconds)
2023-05-30 09:21:22 (8268): Create VM. (boinc_b6a7a9cf74f19744, slot#1)
2023-05-30 09:21:23 (8268): Setting Memory Size for VM. (4000MB)
2023-05-30 09:21:23 (8268): Setting CPU Count for VM. (1)
2023-05-30 09:21:23 (8268): Setting Chipset Options for VM.
2023-05-30 09:21:23 (8268): Setting Graphics Controller Options for VM.
2023-05-30 09:21:24 (8268): Setting Boot Options for VM.
2023-05-30 09:21:24 (8268): Setting Network Configuration for NAT.
2023-05-30 09:21:24 (8268): Enabling VM Network Access.
2023-05-30 09:21:24 (8268): Disabling USB Support for VM.
2023-05-30 09:21:25 (8268): Disabling COM Port Support for VM.
2023-05-30 09:21:25 (8268): Disabling LPT Port Support for VM.
2023-05-30 09:21:25 (8268): Disabling Audio Support for VM.
2023-05-30 09:21:26 (8268): Disabling Clipboard Support for VM.
2023-05-30 09:21:26 (8268): Disabling Drag and Drop Support for VM.
2023-05-30 09:21:26 (8268): Adding storage controller(s) to VM.
2023-05-30 09:21:26 (8268): Adding virtual disk drive to VM. (hostvm_learning.vdi)
2023-05-30 09:21:29 (8268): Adding VirtualBox Guest Additions to VM.
2023-05-30 09:21:29 (8268): Adding network bandwidth throttle group to VM. (Defaulting to 1024GB)
2023-05-30 09:21:30 (8268): Enabling shared directory for VM.
2023-05-30 09:21:30 (8268): Starting VM using VBoxManage interface. (boinc_b6a7a9cf74f19744, slot#1)
2023-05-30 09:21:32 (8268): Error in start VM for VM: 1
Command:
VBoxManage -q startvm "boinc_b6a7a9cf74f19744" --type headless
Output:
VBoxManage.exe: error: The virtual machine 'boinc_b6a7a9cf74f19744' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_b6a7a9cf74f19744" to power on...

2023-05-30 09:21:32 (8268): VM failed to start.
2023-05-30 09:21:32 (8268): Could not start 
2023-05-30 09:21:32 (8268): ERROR: VM failed to start
2023-05-30 09:21:32 (8268): Powering off VM.
2023-05-30 09:21:32 (8268): Deregistering VM. (boinc_b6a7a9cf74f19744, slot#1)
2023-05-30 09:21:32 (8268): Removing network bandwidth throttle group from VM.
2023-05-30 09:21:32 (8268): Removing VM from VirtualBox.

    Hypervisor System Log:

00:00:07.887332          Saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:07.893803          Finished saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml"
00:00:07.894336          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:07.897864          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:08.154136          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:08.158747          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:08.425014          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.425689          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:08.430465          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:08.430666          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 0 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.432827          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:08.436227          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:08.436863          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:08.440254          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:08.694834          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.695320          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 1 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:08.695946          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:08.700849          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:08.961909          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:08.966698          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:09.228681          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:09.232355          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:09.500356          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={431685da-3618-4ebc-b038-833ba829b4b2} aComponent={ExtPackWrap} aText={Failed to locate the cryptographic module 'VBoxPuelCrypto' in extension pack 'Oracle VM VirtualBox Extension Pack'}, preserve=false aResultDetail=0
00:00:09.500404          ERROR [COM]: aRC=VBOX_E_IPRT_ERROR (0x80bb0005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={Couldn't resolve the library path of the crpytographic support module for extension pack 'Oracle VM VirtualBox Extension Pack'}, preserve=false aResultDetail=-1
00:00:09.507981          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.508097          ERROR [COM]: aRC=VBOX_E_OBJECT_NOT_FOUND (0x80bb0001) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={No storage device attached to device slot 0 on port 2 of controller 'Hard Disk Controller'}, preserve=false aResultDetail=0
00:00:09.514179          WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={e54f6256-97a7-4947-8a78-10c013ddf4b8} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND).  The service might not be installed on the host computer}, preserve=true aResultDetail=0
00:00:09.514329          WARNING [COM]: aRC=E_FAIL (0x80004005) aIID={e54f6256-97a7-4947-8a78-10c013ddf4b8} aComponent={HostWrap} aText={Could not load the Host USB Proxy Service (VERR_FILE_NOT_FOUND).  The service might not be installed on the host computer}, preserve=true aResultDetail=0
00:00:09.518095          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:09.773446          Launched VM: 3273418416 pid: 22252 (0x56ec) frontend: headless name: boinc_b6a7a9cf74f19744
00:00:11.168050 Watcher  ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={MachineWrap} aText={The virtual machine 'boinc_b6a7a9cf74f19744' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\Logs\VBoxHardening.log'}, preserve=false aResultDetail=0
00:00:11.168643 Watcher  Reaper: Pid 22252 (0x56ec) exited normally: 1 (0x1)
00:00:11.255521          ERROR [COM]: aRC=E_FAIL (0x80004005) aIID={300763af-5d6b-46e6-aa96-273eac15538a} aComponent={SessionMachine} aText={This machine does not have any snapshots}, preserve=false aResultDetail=0
00:00:11.318809          Saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox" with version "1.19-windows"
00:00:11.323147          Finished saving settings file "C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox"
00:00:11.584129          Saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.587847          Finished saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml"
00:00:11.587949          Saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.591750          Finished saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml"
00:00:11.592802 DeleteVM Saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml" with version "1.12-windows"
00:00:11.596418 DeleteVM Finished saving settings file "C:\Users\hansr\.VirtualBox\VirtualBox.xml"
00:00:16.612828 main     VirtualBox: object deletion starts
00:00:16.612885 main     ERROR [COM]: aRC=VBOX_E_OBJECT_IN_USE (0x80bb000c) aIID={ad47ad09-787b-44ab-b343-a082a3f2dfb1} aComponent={MediumWrap} aText={Medium 'D:\Users\hansr\VirtualBox VMs\Ubuntu\Ubuntu.vdi' cannot be closed because it is still attached to 1 virtual machines}, preserve=false aResultDetail=0
00:00:16.615102 main     HostDnsMonitor: shutting down ...
00:00:16.615160 main     HostDnsMonitor: shut down
00:00:16.616283 Watcher  ERROR [COM]: aRC=E_ACCESSDENIED (0x80070005) aIID={7682d5eb-f00e-44f1-8ca2-99d08b1cd607} aComponent={VirtualBoxWrap} aText={The object is not ready}, preserve=false aResultDetail=0
00:00:16.616744 main     VirtualBox: object deleted

    VM Execution Log:


    VM Startup Log:


    VM Trace Log:

.exe: error: Could not find a registered machine named 'boinc_b6a7a9cf74f19744'
VBoxManage.exe: error: Details: code VBOX_E_OBJECT_NOT_FOUND (0x80bb0001), component VirtualBoxWrap, interface IVirtualBox, callee IUnknown
VBoxManage.exe: error: Context: "FindMachine(Bstr(VMNameOrUuid).raw(), machine.asOutParam())" at line 3139 of file VBoxManageInfo.cpp

2023-05-30 09:21:22 (8268): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC\slots\1/vm_image.vdi" 
Exit Code: -2135228412
Output:
VBoxManage.exe: error: Could not find file for the medium 'C:\ProgramData\BOINC\slots\1\vm_image.vdi' (VERR_FILE_NOT_FOUND)
VBoxManage.exe: error: Details: code VBOX_E_FILE_ERROR (0x80bb0004), component MediumWrap, interface IMedium, callee IUnknown
VBoxManage.exe: error: Context: "OpenMedium(Bstr(pszFilenameOrUuid).raw(), enmDevType, enmAccessMode, fForceNewUuidOnOpen, pMedium.asOutParam())" at line 201 of file VBoxManageDisk.cpp

2023-05-30 09:21:22 (8268): 
Command: VBoxManage -q createvm --name "boinc_b6a7a9cf74f19744" --basefolder "C:\ProgramData\BOINC\slots\1" --ostype "Linux26_64" --register
Exit Code: 0
Output:
Virtual machine 'boinc_b6a7a9cf74f19744' is created and registered.
UUID: d9d7d4c9-9704-4e50-b04d-af2df5765f5b
Settings file: 'C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\boinc_b6a7a9cf74f19744.vbox'

2023-05-30 09:21:23 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --description "virtualbox_28_35599_1685430002.4843874_0" 
Exit Code: 0
Output:

2023-05-30 09:21:23 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --memory 4000 
Exit Code: 0
Output:

2023-05-30 09:21:23 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --cpus 1 
Exit Code: 0
Output:

2023-05-30 09:21:23 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --acpi on --ioapic on --rtcuseutc off 
Exit Code: 0
Output:

2023-05-30 09:21:24 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --vram 16 --graphicscontroller VBoxVGA 
Exit Code: 0
Output:

2023-05-30 09:21:24 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --boot1 disk --boot2 dvd --boot3 none --boot4 none 
Exit Code: 0
Output:

2023-05-30 09:21:24 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --nic1 nat --natdnsproxy1 on --cableconnected1 off 
Exit Code: 0
Output:

2023-05-30 09:21:24 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --cableconnected1 on 
Exit Code: 0
Output:

2023-05-30 09:21:25 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --usb off 
Exit Code: 0
Output:

2023-05-30 09:21:25 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --uart1 off --uart2 off 
Exit Code: 0
Output:

2023-05-30 09:21:25 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --lpt1 off --lpt2 off 
Exit Code: 0
Output:

2023-05-30 09:21:26 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --audio none 
Exit Code: 0
Output:
Warning: --audio is deprecated and will be removed soon. Use --audio-driver instead!

2023-05-30 09:21:26 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --clipboard disabled 
Exit Code: 0
Output:

2023-05-30 09:21:26 (8268): 
Command: VBoxManage -q modifyvm "boinc_b6a7a9cf74f19744" --draganddrop disabled 
Exit Code: 0
Output:

2023-05-30 09:21:26 (8268): 
Command: VBoxManage -q storagectl "boinc_b6a7a9cf74f19744" --name "Hard Disk Controller" --add "sata" --controller "IntelAHCI" --hostiocache off --portcount 3
Exit Code: 0
Output:

2023-05-30 09:21:27 (8268): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/parlea.ru_boinctest/hostvm_learning.vdi" 
Exit Code: 0
Output:
UUID:           e6ac8f64-0f64-48e8-8f0a-aaa962053b20
Parent UUID:    base
State:          created
Type:           multiattach
Location:       C:\ProgramData\BOINC\projects\parlea.ru_boinctest\hostvm_learning.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       25600 MBytes
Size on disk:   9689 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2023-05-30 09:21:27 (8268): 
Command: VBoxManage -q storageattach "boinc_b6a7a9cf74f19744" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/parlea.ru_boinctest/hostvm_learning.vdi" 
Exit Code: -2135228409
Output:
VBoxManage.exe: error: Cannot attach medium 'C:\ProgramData\BOINC\projects\parlea.ru_boinctest\hostvm_learning.vdi': the media type 'MultiAttach' can only be attached to machines that were created with VirtualBox 4.0 or later
VBoxManage.exe: error: Details: code VBOX_E_INVALID_OBJECT_STATE (0x80bb0007), component SessionMachine, interface IMachine, callee IUnknown
VBoxManage.exe: error: Context: "AttachDevice(Bstr(pszCtl).raw(), port, device, DeviceType_HardDisk, pMedium2Mount)" at line 785 of file VBoxManageStorageController.cpp

2023-05-30 09:21:27 (8268): 
Command: VBoxManage -q closemedium "C:\ProgramData\BOINC/projects/parlea.ru_boinctest/hostvm_learning.vdi" 
Exit Code: 0
Output:

2023-05-30 09:21:28 (8268): 
Command: VBoxManage -q showhdinfo "C:\ProgramData\BOINC/projects/parlea.ru_boinctest/hostvm_learning.vdi" 
Exit Code: 0
Output:
UUID:           e6ac8f64-0f64-48e8-8f0a-aaa962053b20
Parent UUID:    base
State:          created
Type:           normal (base)
Location:       C:\ProgramData\BOINC\projects\parlea.ru_boinctest\hostvm_learning.vdi
Storage format: VDI
Format variant: dynamic default
Capacity:       25600 MBytes
Size on disk:   9689 MBytes
Encryption:     disabled
Property:       AllocationBlockSize=1048576

2023-05-30 09:21:29 (8268): 
Command: VBoxManage -q storageattach "boinc_b6a7a9cf74f19744" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium "C:\ProgramData\BOINC/projects/parlea.ru_boinctest/hostvm_learning.vdi" 
Exit Code: 0
Output:

2023-05-30 09:21:29 (8268): 
Command: VBoxManage -q storageattach "boinc_b6a7a9cf74f19744" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --medium none 
Exit Code: 0
Output:

2023-05-30 09:21:29 (8268): 
Command: VBoxManage -q storageattach "boinc_b6a7a9cf74f19744" --storagectl "Hard Disk Controller" --port 0 --device 0 --type hdd --mtype multiattach --medium "C:\ProgramData\BOINC/projects/parlea.ru_boinctest/hostvm_learning.vdi" 
Exit Code: 0
Output:

2023-05-30 09:21:29 (8268): 
Command: VBoxManage -q storageattach "boinc_b6a7a9cf74f19744" --storagectl "Hard Disk Controller" --port 1 --device 0 --type dvddrive --medium "D:\Program Files\Oracle\VirtualBox/VBoxGuestAdditions.iso" 
Exit Code: 0
Output:

2023-05-30 09:21:30 (8268): 
Command: VBoxManage -q bandwidthctl "boinc_b6a7a9cf74f19744" add "boinc_b6a7a9cf74f19744_net" --type network --limit 1024G 
Exit Code: 0
Output:

2023-05-30 09:21:30 (8268): 
Command: VBoxManage -q sharedfolder add "boinc_b6a7a9cf74f19744" --name "shared" --hostpath "C:\ProgramData\BOINC\slots\1/shared"
Exit Code: 0
Output:

2023-05-30 09:21:32 (8268): 
Command: VBoxManage -q startvm "boinc_b6a7a9cf74f19744" --type headless
Exit Code: 1
Output:
VBoxManage.exe: error: The virtual machine 'boinc_b6a7a9cf74f19744' has terminated unexpectedly during startup with exit code 1 (0x1).  More details may be available in 'C:\ProgramData\BOINC\slots\1\boinc_b6a7a9cf74f19744\Logs\VBoxHardening.log'
VBoxManage.exe: error: Details: code E_FAIL (0x80004005), component MachineWrap, interface IMachine
Waiting for VM "boinc_b6a7a9cf74f19744" to power on...

2023-05-30 09:21:32 (8268): 
Command: VBoxManage -q snapshot "boinc_b6a7a9cf74f19744" list 
Exit Code: -108
Output:
This machine does not have any snapshots

2023-05-30 09:21:32 (8268): 
Command: VBoxManage -q bandwidthctl "boinc_b6a7a9cf74f19744" remove "boinc_b6a7a9cf74f19744_net" 
Exit Code: 0
Output:

2023-05-30 09:21:32 (8268): 
Command: VBoxManage -q unregistervm "boinc_b6a7a9cf74f19744" --delete 
Exit Code: 0
Output:
0%...10%...20%...30%...40%...50%...60%...70%...80%...90%...100%

09:21:38 (8268): called boinc_finish(1)

</stderr_txt>
]]>


©2025 COPYRIGHT HOLDER